Part Description:
Fusible Safety Switch; Type Heavy Duty Safety; AC Voltage Rating 480/600 V; DC Voltage Rating 250/600 V; Current Rating 60 Ampere; Power Rating 5 HP at 480 VAC, 10 HP at 600 VAC, 15 HP at 480/600 VAC 3-Phase (Standard), 20 HP at 480 VAC, 25 HP at 600 VAC 1-Phase, 30 HP at 480 VAC, 50 HP at 600 VAC 3-Phase (Maximum for Time Delay Fuse), 10 HP at 250 VDC, 30 HP at 600 VDC; Number of Poles 3; Number of Wires 3; Fuse Provision Fusible; Fuse Type Class H/J/R, Time Delay; Neutral Type No; Enclosure NEMA 1; Size 11.53 Inch W x 10.17 Inch D x 17.46 Inch H; Approval UL 98; Number of Fuses 3; Applicable Standard NEMA KS-1-1990, CBC; Application Grounded Wye System Service Entrance Equipment

UPC:  78364315101

Part Number: 118381

UNSPSC: 39122233

Status:  STOCK

Create Label

HF362

SIE HF362 SIE 600V 3P 60A N1 FUSED SAFETY SW

SIE HF362 SIE 600V 3P 60A N1 FUSED SAFETY SW

SIE HF362 SIE 600V 3P 60A N1 FUSED SAFETY SW

78364315101

Specifications

 AC Voltage Rating 480/600 V
 Approval UL 98
 Country of Origin Mexico
 Current Rating REF 60 A
 DC Voltage Rating 250/600 V
 Enclosure NEMA 1
 Fuse Provision Fusible
 Fuse Type Class H/J/R, Time Delay
 Neutral Type No
 Number Of Poles 3
 Number Of Wires 3
 Package Height 7.480
 Package Length 20.079
 Package Weight 16.689
 Package Width 13.780
 Power Rating 5 HP at 480 VAC, 10 HP at 600 VAC, 15 HP at 480/600 VAC 3-Phase (Standard), 20 HP at 480 VAC, 25 HP at 600 VAC 1-Phase, 30 HP at 480 VAC, 50 HP at 600 VAC 3-Phase (Maximum for Time Delay Fuse), 10 HP at 250 VDC, 30 HP at 600 VDC
 Product Class Single Throw Safety/Disconnect Switch
 Short Description 480/600 VAC, 250 VDC, 60 A, 3-Pole, 3-Wire, NEMA 1, 304 Stainless Steel, Fusible, Heavy Duty, Safety Switch
 Size Ref 11.53 IN x 10.17 IN x 17.46 IN
 Smart Image Thumb 
 Smart Long Desc Fusible Safety Switch; Type Heavy Duty Safety; AC Voltage Rating 480/600 V; DC Voltage Rating 250/600 V; Current Rating 60 Ampere; Power Rating 5 HP at 480 VAC, 10 HP at 600 VAC, 15 HP at 480/600 VAC 3-Phase (Standard), 20 HP at 480 VAC, 25 HP at 600 VAC 1-Phase, 30 HP at 480 VAC, 50 HP at 600 VAC 3-Phase (Maximum for Time Delay Fuse), 10 HP at 250 VDC, 30 HP at 600 VDC; Number of Poles 3; Number of Wires 3; Fuse Provision Fusible; Fuse Type Class H/J/R, Time Delay; Neutral Type No; Enclosure NEMA 1; Size 11.53 Inch W x 10.17 Inch D x 17.46 Inch H; Approval UL 98; Number of Fuses 3; Applicable Standard NEMA KS-1-1990, CBC; Application Grounded Wye System Service Entrance Equipment
 Type Heavy Duty Safety
 